Atlas™ Pump Controllers Available in float operated and 4-20 mA versions, these high end controllers are designed for the municipal and industrial markets.
|
Atlas™ 1 Controller
The Atlas™ 1 float operated simplex pump controller features:
- Power input: fused and transient protected
- Float inputs (3): 24 VDC
- Float and sensor inputs transient protected
- Pump run and pump call indicator lights
- HAND/OFF/AUTO switch
- Pump seal fail input with indicator light
- Pump over temperature input with indicator light
- High level alarm indicator light
- Horn output and input for external mute
- Alarm test push button
- Output for flashing alarm light
- Removable "quick connect" terminal strips for easy service
- UL/cUL Listed
|
 |
| Atlas™ 1 Pump Controller |
|
|
Atlas™ 2 Controller
Atlas™ 2 float operated duplex pump controller features:
- Power input: fused and transient protected
- Float inputs (4): 5 VDC @ 1 mA max
- Float and sensor inputs transient protected
- Pump run and pump call indicator lights
- HAND/OFF/AUTO switches
- Pump seal fail inputs with indicator lights
- Pump over temperature inputs with automatic disable and indicator lights
- High level alarm indicator light
- Horn output and input for external mute
- Alarm test push button
- Output for flashing alarm light
- Pump alternation selector switch
- Automatically demote pump with seal fail condition to lag pump
- Built-in delay for pump starts and pump stops
- Removable "quick connect" terminal strips for easy service
- UL/cUL Listed
|
 |
| Atlas™ 2 Pump Controller |
|
|
Atlas™ 3 Pump Controller
The Atlas™ 3 float operated duplex pump controller features:
- Power input: fused and transient protected
- Float inputs (5): 5 VDC @ 26 mA max*
- Float and sensor inputs transient protected
- Pump run lights
- Pump alternation switch
- Pump seal fail inputs with indicator lights
- Pump over temperature inputs with automatic disable and indicator lights
- Switch selectable for latch to require manual reset*
- Output for flashing alarm light
- Relay output for alarm horn with mute reset or common alarm*
- High alarm indicator light
- Low alarm indicator light*
- Push to Test float switches with indicator lights*
- Float out of order detection with indicator lights*
- Fail to start test (switch selectable, enable/disable)*
- Pump disable inputs (can be used for SCADA, etc.)*
- Optional serial port for communication (Modbus)*
- Built-in delay for pump starts and pump stops
- Automatically demote pump with seal fail condition to lag pump
- Removable "quick connect" terminal strips for easy service
- UL/cUL Listed
*Indicates additional features above the Atlas™ 2 controller.
|
 |
| Atlas™ 3 Pump Controller |
|
|
Atlas™ 4 Pump Controller
The Atlas™ 4 4-20 mA transducer operated pump controller features a 32 alpha-numeric LCD display for level, status and setpoint information. It has a simple menu structure for easy display and modification of setpoints and set up configuration. Built-in software, so no programming is required.
- Alternation selection switch on front panel to turn alternation on or select the lead pump is alternation is off
- Built-in elapsed time meters for all pumps
- 4-20 mA main sensor input with loop power supply for easy connection to most transducers and transmitters
- Pump seal fail and over temperature inputs with indication
- Scalable 4-20 mA level output transmitter
- Built-in single float backup system
- Auxiliary inputs (3)
- Built in horn relay with input for external mute button
- Relay outputs for both high and low level alarms
- Individually selectable setpoints for up to three pumps
- All inputs are filtered and transient protected
- UL/cUL Listed
|
 |
| Atlas™ 4 Pump Controller |
|
|
 |
| Altas™ 4 Integrated System |
|
|
|